카페검색 본문
카페글 본문
-
Valve Seat Leakage Rates Comparison 2023.07.29해당카페글 미리보기
Valve Seat Leakage Rates Comparison Table provides a convenient tool to compare valve seat leakage rates for isolation valves (metallic and non-metallic) as per various standards. www.piping-world.com leak-class...
-
Isolation Valves - Linear Movement 2011.09.18해당카페글 미리보기
Allow the removal of equipment - Allow the shut down of plant A multitude of different types and designs of isolation valve have been developed in order to meet this range of applications and the diverse operating conditions in which...
-
Check valve 2007.12.09해당카페글 미리보기
Although check valves can effectively shut off reverse flow, they should never be used in place of an isolation valve to contain live steam, in a section of pipe. As with isolation valves, there are a number of different check valve...
-
HRSG 설계_절차 및 방법 2023.07.11해당카페글 미리보기
ü The HP steam line from each HRSG is provided with a safety valve, a non return valve, a motor operated main steam isolation valve (by other). l LP System Flow Path ü The source of feedwater flow into the LP system is from the...
-
급수계통 2023.06.01해당카페글 미리보기
f. OPEN/CLOSE Time : 6-10 sec. (Downcomer), 14-18 sec.(Economizer) 3.6. 주급수 차단 밸브 (MFIV: Main Feedwater Isolation Valve) : 8대 a. 제 작 사 : Edward b. Type : Pressure Seal Equiwedge Gate c.유 량 : 14,800 gpm(Economizer), 1,700 gpm...
-
Re: 탄성섬유의 노화과정!! 2021년 2025.01.04해당카페글 미리보기
mitral valve prolapse, aortic enlargement, skin and skeletal findings MD molecular dynamics MFS Marfan syndrome MMP matrix metalloproteinase Neu-1 neuraminidase-1 NMR nuclear magnetic resonance PCOS polycystic ovary syndrome PPCA...
-
VEGETABLE OIL 양하시 IGG BRANCH VALVE를 CLOSE하는것이 맞지 않은가요. 2012.10.30해당카페글 미리보기
IGG가 장착된 케미칼탱커선에서 식용유 양하시 IGG BRANCH VALVE를 CLOSE하는것이 맞다고 보는데 왜 OPEN하지 않았다고 지적을...correctly? Observations : Vessel was provided with permitted isolation of individual tanks from common venting...
-
MPS of Electric Parts for Cement Grinding Mill 2023.09.22해당카페글 미리보기
positioning, valve position, chute position, brake position and similar application where required. 3) Level detectors Types of level detectors vary for individual applications. All bins, silos and other means of storage shall have level...
-
[PMDG 737] Schwechat(LOWW) - Madeira(LPMA) 신가희 부기장 컴백 2004.09.15해당카페글 미리보기
LIGHT ON 합니다.. APU ON, APU GEN ON APU BLEED ON, L PACK AUTO.. APU 는 LEFT PACK 과 연결되어 있기때문에 ISOLATION VALVE 를 열어주고 R PACK AUTO.. Yaw Damper on.. Probe Heat ON.. / Window Heat ON.. 꺼두었던 Elec Driven HYD Pump 도 ON...
-
B767-300F ATA 29 HYDRAULIC POWER 2020.12.03해당카페글 미리보기
된다. 이 때 밸브가 닫힌 상태로 5분 이상 엔진을 작동하게 되면 EDP에 손상을 줄 수 있다. 추가로 꼬리 부분에도 isolation valve가 있어 정비를 위해 꼬리날개 부분의 유압을 차단할 수도 있다. ACMP는 115vac 3상을 공급 받으며 OFF AUTO ON의 총 3가지...